Schneider Electric – Zelio Time timing relays and timers
Function
A
Ac
Act
Ad
Ah
Ak
Akt
At
Aw
B
Bw
C
Ct
D
Di
Dit
Diw
Dt
Dw
H
He
Ht
Hw
K
L
Li
Lit
Lt
N
O
P
Pt
Q
Qc
Qe
Qg
Qgt
Qt
Qtt
Tl
Tt
W
Wt
Description
Power ON-delay relay
ON-delay and OFF-delay relay with control signal
ON-delay and OFF-delay relay with control signal and pause/summation control signal
Pulse delayed relay with control signal
Pulse delayed relay (single cycle) with control signal
Asymmetrical ON-delay and OFF-delay relay with control signal
Asymmetrical ON-delay and OFF-delay relay with control signal and pause/summation control signal
Power ON-delay relay with pause/summation control signal
Power ON-delay relay with retrigger/restart control signal
Single interval relay with control signal
Double interval relay with control signal
OFF-delay relay with control signal
OFF-delay relay with control signal and pause/summation control signal
Symmetrical fashing relay (starting pulse-OFF)
Symmetrical fashing relay (starting pulse-ON)
Symmetrical fashing relay (starting pulse-ON) with pause/summation control signal
Symmetrical fashing relay (starting pulse-ON) with retrigger/restart control signal
Symmetrical fashing relay (starting pulse-OFF) with pause/summation control signal
Symmetrical fashing relay (starting pulse-OFF) with retrigger/restart control signal
Interval relay
Pulse-ON de-energization
Interval relay with pause/summation control signal
Ineterval relay with retrigger/restart control signal
Delay on de-energization (without auxiliary supply)
Asymmetrical flashing relay (starting pulse-OFF)
Asymmetrical fashing relay (starting pulse-ON)
Asymmetrical fashing relay (starting pulse-ON) with pause/summation control signal
Asymmetrical fashing relay (starting pulse-OFF) with pause/summation control signal
Safe-guard relay
Delayed Safe-guard relay
Pulse delayed relay with fxed pulse length
Pulse delayed relay with fxed pulse length and pause/summation control signal
Star-delta relay (2 NO outputs with same common)
Star-delta relay (1 CO output)
Star-delta relay (1 NC + 1 NO outputs with split common)
Star-delta relay (2 CO outputs with same common)
Star-delta relay (2 CO outputs with same common) with pause/summation control signal
Star-delta relay (2 CO outputs with split common)
Star-delta relay (2 CO outputs with split common) with pause/summation control signal
Bistable relay with control signal on
Retriggerable bistable relay with control signal on
Interval relay with control signal OFF
Interval relay with control signal OFF and pause/summation control signal
Time graph
(1 output)
(1 output)
(1 output)
(1 output)
(1 output)
(1 output)
(1 output)
(1 output)
(1 output)
(1 output)
(1 output)
(1 output)
(1 output)
(1 output)
(1 output)
(1 output)
(1 output)
(1 output)
(1 output)
(1 output)
(1 output)
(1 output)
(1 output)
(1 output)
(1 output)
(1 output)
(1 output)
(1 output)
(1 output)
(1 output)
(1 output)
(1 output)
(1 output)
(1 output)
(1 output)
(1 output)
(1 output)
(1 output)
(1 output)
(1 output)
(1 output)
(1 output)
(1 output)
(1 output)
(1 output)
(1 output)
(1 output)
(1 output)
(1 output)
(1 output)
(1 output)
(1 output)
(1 output)
(1 output)
(1 output)
(1 output)
(1 output)
(1 output)
(1 output)
(1 output)
(1 output)
(1 output)
(1 output)
(1 output)
(1 output)
(1 output)
(1 output)
(1 output)
(1 output)
(1 output)
(1 output)
(1 output)
(1 output)
<
Remarks
Except for RE17⬤, RE22R2AMU,RE22R2MMW, RE22R2MMU, and RE22R2MJU, timing can be interrupted / paused each time Y1 closes. When the cumulative total time elapsed reaches the preset value T, the output(s) R close(s).
Function D with Y1 is only for the RE17 range and RE22R2MJU, RE22R2MMU, and RE22R2MMW references.
For RE17⬤, RE22R2MMW, RE22R2MMU, and RE22R2MJU, timing can be interrupted/paused each time Y1 closes.
Function L with Y1 is only for the RE17 range.