RE22R1CMRZelio TimeModular timing relayRE2224…240 V AC/DC 50/60 Hz20 m/s2 (f= 10 to 150 Hz)
conforming to IEC 60068-2-615 gn not operating for 11 ms conforming to IEC 60068-2-27
5 gn in operation for 11 ms conforming to IEC 60068-2-278 A2000 VA8 A250 V AC100000 cycles, 8 A at 250 V, AC-1
100000 cycles, 2 A at 24 V, DC-110000000 cycles22.5 mm0.1 kgIP40 housing: conforming to IEC 60529
IP50 front face: conforming to IEC 60529
IP20 terminals: conforming to IEC 605293 conforming to IEC 60664-1Fast transients immunity test – test level: 1 kV level 3 (capacitive connecting clip) conforming to IEC 61000-4-4
Surge immunity test – test level: 1 kV level 3 (differential mode) conforming to IEC 61000-4-5
Surge immunity test – test level: 2 kV level 3 (common mode) conforming to IEC 61000-4-5
Electrostatic discharge – test level: 6 kV level 3 (contact discharge) conforming to IEC 61000-4-2
Electrostatic discharge – test level: 8 kV level 3 (air discharge) conforming to IEC 61000-4-2
Radiated radio-frequency electromagnetic field immunity test – test level: 10 V/m level 3 (80 MHz…1 GHz) conforming to IEC 61000-4-3
Conducted RF disturbances – test level: 10 V level 3 (0.15…80 MHz) conforming to IEC 61000-4-6
Fast transient bursts – test level: 2 kV level 3 (direct contact) conforming to IEC 61000-4-4
Immunity to microbreaks and voltage drops – test level: 30 % (500 ms) conforming to IEC 61000-4-11
Immunity to microbreaks and voltage drops – test level: 100 % (20 ms) conforming to IEC 61000-4-11UL 508
IEC 61812-195 % at 25 to 55 ℃-20 to 60 ℃-40 to 70 ℃UL
CE
CCC
CSA
China RoHS
GL
RCM
EACGreen Premium productPro-active compliance
(Product out of EU RoHS legal scope) EU RoHS DeclarationYesYesChina RoHS declarationProduct Environmental ProfileEnd of Life InformationREACH Declaration50…60 Hz +/- 5 %0.6 to 1 N.m conforming to
IEC 60947-1Relay10 mA at 5 V DCIII conforming to
IEC 60664-11 C/O timed contact, cadmium freeScrew terminals, 1 x 0.5…1 x 3.3 mm2 (AWG 20…AWG 12) solid without cable end
Screw terminals, 2 x 0.5…2 x 2.5 mm2 (AWG 20…AWG 14) solid without cable end
Screw terminals, 1 x 0.2…1 x 2.5 mm2 (AWG 24…AWG 14) flexible with cable end
Screw terminals, 2 x 0.2…2 x 1.5 mm2 (AWG 24…AWG 16) flexible with cable end100 MOhm at 500 V DC conforming to IEC 60664-1MTTFd = 205.4 years
B10d = 190000LED backlight green (steady) for dial pointer indication
LED yellow (steady) for output relay energised
LED yellow (fast flashing) for timing in progress and output relay de-energised
LED yellow (slow flashing) for timing in progress and output relay energisedRotary knob
Diagnostic button
Potentiometer external35 mm DIN rail conforming to EN/IEC 6071510 ms2.5 kV for 1 mA/1 minute at 50 Hz between relay output and power supply with basic insulation conforming to IEC 61812-1Any positionSelf-extinguishing2004/108/EC – electromagnetic compatibility
2006/95/EC – low voltage directive3 VA at 240 V AC1.5 W at 240 V DC+/- 0.5 % conforming to
IEC 61812-1+/- 0.05 %/℃10…100 s
3…30 s
0.05…1 s
30…300 s
30…300 h
30…300 min
3…30 min
3…30 h
0.3…3 s
1…10 sC
Ct0.85…1.1 Us+/- 0.2 %/V+/- 10 % of full scale at 25 ℃
conforming to IEC 61812-1100 ms with load in
parallel
30 ms100 ms4 kV/3 conforming to
IEC 60664-1<= 2.4 V120 ms on
de-energisation5 kV for 1.2 to 50 µs
conforming to IEC 60664-1
conforming to IEC 60068-2-615 gn not operating for 11 ms conforming to IEC 60068-2-27
5 gn in operation for 11 ms conforming to IEC 60068-2-278 A2000 VA8 A250 V AC100000 cycles, 8 A at 250 V, AC-1
100000 cycles, 2 A at 24 V, DC-110000000 cycles22.5 mm0.1 kgIP40 housing: conforming to IEC 60529
IP50 front face: conforming to IEC 60529
IP20 terminals: conforming to IEC 605293 conforming to IEC 60664-1Fast transients immunity test – test level: 1 kV level 3 (capacitive connecting clip) conforming to IEC 61000-4-4
Surge immunity test – test level: 1 kV level 3 (differential mode) conforming to IEC 61000-4-5
Surge immunity test – test level: 2 kV level 3 (common mode) conforming to IEC 61000-4-5
Electrostatic discharge – test level: 6 kV level 3 (contact discharge) conforming to IEC 61000-4-2
Electrostatic discharge – test level: 8 kV level 3 (air discharge) conforming to IEC 61000-4-2
Radiated radio-frequency electromagnetic field immunity test – test level: 10 V/m level 3 (80 MHz…1 GHz) conforming to IEC 61000-4-3
Conducted RF disturbances – test level: 10 V level 3 (0.15…80 MHz) conforming to IEC 61000-4-6
Fast transient bursts – test level: 2 kV level 3 (direct contact) conforming to IEC 61000-4-4
Immunity to microbreaks and voltage drops – test level: 30 % (500 ms) conforming to IEC 61000-4-11
Immunity to microbreaks and voltage drops – test level: 100 % (20 ms) conforming to IEC 61000-4-11UL 508
IEC 61812-195 % at 25 to 55 ℃-20 to 60 ℃-40 to 70 ℃UL
CE
CCC
CSA
China RoHS
GL
RCM
EACGreen Premium productPro-active compliance
(Product out of EU RoHS legal scope) EU RoHS DeclarationYesYesChina RoHS declarationProduct Environmental ProfileEnd of Life InformationREACH Declaration50…60 Hz +/- 5 %0.6 to 1 N.m conforming to
IEC 60947-1Relay10 mA at 5 V DCIII conforming to
IEC 60664-11 C/O timed contact, cadmium freeScrew terminals, 1 x 0.5…1 x 3.3 mm2 (AWG 20…AWG 12) solid without cable end
Screw terminals, 2 x 0.5…2 x 2.5 mm2 (AWG 20…AWG 14) solid without cable end
Screw terminals, 1 x 0.2…1 x 2.5 mm2 (AWG 24…AWG 14) flexible with cable end
Screw terminals, 2 x 0.2…2 x 1.5 mm2 (AWG 24…AWG 16) flexible with cable end100 MOhm at 500 V DC conforming to IEC 60664-1MTTFd = 205.4 years
B10d = 190000LED backlight green (steady) for dial pointer indication
LED yellow (steady) for output relay energised
LED yellow (fast flashing) for timing in progress and output relay de-energised
LED yellow (slow flashing) for timing in progress and output relay energisedRotary knob
Diagnostic button
Potentiometer external35 mm DIN rail conforming to EN/IEC 6071510 ms2.5 kV for 1 mA/1 minute at 50 Hz between relay output and power supply with basic insulation conforming to IEC 61812-1Any positionSelf-extinguishing2004/108/EC – electromagnetic compatibility
2006/95/EC – low voltage directive3 VA at 240 V AC1.5 W at 240 V DC+/- 0.5 % conforming to
IEC 61812-1+/- 0.05 %/℃10…100 s
3…30 s
0.05…1 s
30…300 s
30…300 h
30…300 min
3…30 min
3…30 h
0.3…3 s
1…10 sC
Ct0.85…1.1 Us+/- 0.2 %/V+/- 10 % of full scale at 25 ℃
conforming to IEC 61812-1100 ms with load in
parallel
30 ms100 ms4 kV/3 conforming to
IEC 60664-1<= 2.4 V120 ms on
de-energisation5 kV for 1.2 to 50 µs
conforming to IEC 60664-1